How to maintain high temperature oil pump

High-temperature oil pump is a positive displacement pump, work rely on the main, driven gear intermeshing changes in the volume of work to transport the melt. Its structure and performance make it widely used in different industries and promotion, to withstand high temperatures, with good sealing performance at high temperatures, the pump industry is a major leap in technology. But in the actual operation of how to maintain the high temperature pump it? Here we do a few analysis: High temperature pump routine maintenance (l) pump disintegration and cleaning, heating, cooling, starting and stopping should be strictly in accordance with the provisions of the operation, in order to avoid undue losses. (2) Care should be taken to maintain the stability of the population pressure of the booster pump so that it has a stable volumetric efficiency in favor of the pump itself and the stability of the downstream spinning quality. (3) The population is negative pressure of the packing shaft seal pump, packing should be kept at a pressure higher than the atmospheric pressure. When the back pressure is reduced, the pressure of the stuffing box should be adjusted in time, otherwise the pump will be sucked into the air and the belt will be broken. This will affect the pelletizing and cause the discharge of the pelletizer. (4) to check the temperature of the heat medium jacket, the main body and the front and back cover of the heat medium temperature to be consistent. (5) Every time the output increases, it is necessary to record the output, speed, output, inlet pressure and current value at the time, and compare the data before and after, and carefully analyze them so as to find the anomalies as soon as possible and deal with them in time.

Level Transmitter

The liquid level transmitter can convert the changes of various level parameters into analog signals, and transmit them to the control room remotely for centralized display, alarm or automatic control of secondary instruments or computers. Its good structure and installation method can be applied to the continuous detection of liquid level, material level or material level under special conditions such as high temperature, high pressure, strong corrosion, easy crystallization, anti-clogging, anti-cold junction, and solid powdery and granular materials. , can be widely used in detection and control in various industrial processes.

Liquid level transmitters can be applied to liquid Level Measurement and control in industrial sites, rural water supply and sewage treatment, petroleum, chemical industry, power plants, hydrological monitoring, reservoirs, dams, hydropower construction and other fields of liquid level measurement and control. Liquid level transmitters have input type, straight rod type, flange type, threaded type, inductive type, screw-in type, floating ball structure design, with anti-blocking type design, simple device, convenient use and strong interchangeability , The high-quality sensor has high sensitivity and fast response speed, accurately reflects the slight changes in the flow or static liquid level, and has high measurement accuracy.

Advantages of Level Transmitters

1. The device is simple, easy to use, and has strong interchangeability.

2. It is suitable for measuring the liquid level and interface of the liquid medium in the container. In addition to on-site instructions, it can also be equipped with remote transmitters, alarm switches, and complete detection functions.

3. The reading is intuitive and eye-catching, and the direction of the observation indicator can be changed according to the user's needs.

4. The measurement range is large, not limited by the height of the storage tank.

5. The indicating mechanism is completely isolated from the measured medium, with good sealing performance, high reliability and safe use.

6. Simple structure, convenient installation, convenient maintenance, corrosion resistance, no power supply, explosion-proof.

7. The high-quality sensor has high sensitivity and fast response speed, accurately reflects the slight changes of flowing or static liquid level, and has high measurement accuracy.

8. With intrinsically safe explosion-proof and isolated explosion-proof capabilities, it can be used in various dangerous places.

9. With anti-blocking design, it can realize the measurement of the liquid level of paste medium.

10.100% equal division scale, LED/LCD indicator head, very convenient to read on site.

11.4~20mA two-wire signal transmission, strong anti-interference ability and long transmission distance.

12. Exquisite and unique zero point, full scale, and nonlinear compensation ensure the accuracy and stability of the instrument within the range of operating conditions.

13. The Pressure Sensor directly senses the liquid level pressure and is not affected by the foaming and accumulation of the medium.

14. Wide range of tested media can be used, such as oil, water and paste, with certain anti-corrosion ability.

Classification of liquid level transmitters

1. Single flange liquid level transmitter

Single-flange liquid level transmitters have flat flanges and flange liquid level transmitters with insert barrels, both of which are suitable for single-flange liquid level transmitters that use the gravity of the medium to be measured to measure the height of the liquid level. For medium with high viscosity and easy crystallization, it is generally used in open containers or equipment installations.

4 20ma 1 5v Output Pool Water Level Sensor Sewage Level Sensor 304sst Tank Level Sensor3

2. Double flange liquid level transmitter

The double-flange liquid level transmitter is a Differential Pressure Transmitter, which provides a reliable measurement method to prevent the measured medium from directly contacting the isolation diaphragm of the transmitter. The main features are the need to isolate the high-temperature medium from the transmitter, the measurement medium has a corrosive effect on the sensitive components of the transmitter, the suspension liquid or high-viscosity medium, the measured medium solidifies or crystallizes due to changes in the environment or process temperature, and the measured medium is replaced It needs to be strictly purified to measure the first class. Double flange liquid level transmitter is mainly used in the measurement of liquid level in sealed pressure vessels.

Submersible Digital Differential Pressure Sensor Steam Silicon Resonant Transmitter1

3. Submersible liquid level transmitter

The submersible liquid level transmitter has rod type and arm type. Its principle is based on the principle that the measured liquid static pressure is proportional to the height of the liquid. It uses the piezoresistive effect of diffused silicon or ceramic sensitive elements to convert the static pressure into electricity. Signal. After temperature compensation and linear correction, it is converted into 4~20mA current signal output. Due to the characteristics of this transmitter, such as convenient installation, strong adaptability, etc., it can perform high-precision measurement from water, oil to paste with high viscosity, and is not affected by the foaming and accumulation of the measured medium. It is generally used in open Devices for mouthpieces or equipment.

4 20ma 1 5v Output Pool Water Level Sensor Sewage Level Sensor 304sst Tank Level Sensor5

Level Transmitter,Differential Pressure Level Transmitter,Submersible Level Transmitter,Level Gauge

Wuxi Winsun Automation Instrument Co., Ltd , https://www.jswxwinsun.com