Geothermal return pipe is not hot how to do warm and no heat how to deal with

As the winter arrives, the weather will get colder and colder, especially in the north, so every household in the north will open up the floor for heating. So, what if the geothermal return pipe is not hot ? How to deal with it if it is warm and not hot? If your family encounters such a situation, we can look at the content of this article and hope to solve the problem for you.

1. How to do if the geothermal return pipe is not hot : The pipeline pressure is not enough

Because the floor is too high to be heated to the end, the excessive pressure on the pipeline leads to unsatisfactory heating. Solution: If the pipeline pressure is not enough, you can directly find the property or heating company to solve, if it still can not be resolved, it can be recommended to install a circulating pump to improve the hot water supply to achieve the desired results.

2 geothermal return pipe is not hot how to do : pipeline gas

Because of the warmth and heat of the ground, the backwater bar is not hot, and the gas in the pipeline is hindered, so that hot water cannot be circulated back and forth. Solution: Close the water return valve first, and then open the warm floor exhaust valve to discharge the gas in the pipe, and then close the water inlet valve. There may be water overflow during this process. You may find a pot in advance to take the water. When the gas is completely drained, open the water pipe.

3 geothermal return pipe is not hot how to do : filter clogging

First find a live spanner, open the filter, and then perform the filter cleaning. After cleaning, reinstall it. If you do not operate it, you can also look for a professional to handle it.

4 geothermal return pipe is not hot how to do : loop uneven

In this case, the small valve on the warm water separator can be used to adjust the circulation of each circuit, so that the circulation can be uniform, so that the heating effect can be achieved.

5 geothermal return pipe is not hot how to do : the valve is not open

If there is hot water in the inlet and no hot water in the return water, it means that the valve is not open. The first step is to check which valve is not open, and if it is not open, it should be opened in time to solve the problem that the warm water return pipe is not hot.

6 geothermal return pipe is not hot how to do : geothermal construction issues

Sometimes the quality of construction workers is low, or there is no professional training, construction is more barbaric, resulting in the emergence of dead bends in the pipeline, flattening phenomenon, resulting in poor water flow, increased resistance, and there is a row of pipe spacing does not meet the design requirements. There is also that the floor heating pipe is not cleaned of impurities in the pipe before it is installed, it is kept clean, and the pipe is clogged.

Xiao Bian summary: geothermal return pipe is not hot how to do ? how to deal with the floor heating is not hot? The above Xiao Bian summary of the six causes of geothermal return pipe is not hot, and gives a solution to provide everyone with learning and reference, hope more The content shared can be provided for everyone to help.