As the times progressed, various kinds of heating equipment entered our home. Among them, floor heating has gradually become the mainstream product of our home heating system. The floor heating products on the market are constantly increasing. Wall-warming floor heating is one of them. If the wall-warming boiler is not warm, how do we do it? Today we will take a look at the heating of boilers .
[wall heater heating is not hot]
Reason 1, the lack of hot water, the pressure is not enough to warm the working pressure can not be less than 0.6MPa, the pressure is lower than 0.6MPa when the floor heating system can not work, resulting in warm and not hot, need to re-inject water to the boiler to suppress At 0.6MPa. It is normal for the pressure to always drop when you first use the floor heating system because the gas in the system needs to be drained. However, if you continue to use it for a long time, you must ask a professional to investigate and find out the reasons for repairs.
Reason 2: The length of the heating coil is too long for the pipeline. It is not how long it takes for the disk to be long. Generally, a heating loop for one loop cannot exceed 100 meters, and the lengths of the two loops in the same manifold are the same. The difference should not exceed 20 meters, otherwise it will lead to uneven hot water distribution, resulting in warm and not hot.
Cause 3: Due to the difference in water quality, some areas of the district have a problem with water quality. After heating in some areas for a long time, scale will be generated in the floor heating pipes and the floor heating coils will be blocked. This will cause the floor heating to be not hot. At this time, professional floor heating personnel should be invited to clean the floor. In order to avoid this situation, users are advised to install a simple water purification system when installing water to warm the floor to prevent the floor heating coil from being clogged with scale.
Cause 4: The water pressure inside the boiler is too low to reach the start-up standard. In this case, the boiler will automatically alarm to pressurize.
Cause 5. The area of ​​boiler and floor heating does not match. At the time of purchase, it is necessary to recognize the heating area. It is recommended that the area of ​​the boiler be better than the actual area of ​​about 80 square meters. The so-called big horse-drawn car is a good guarantee.
Cause 6. The length of the heating coil is too long. If it is planned to install a wall-hung boiler, it is necessary to negotiate with the warm-installing company in advance. It is recommended that each pipe requires about 60 meters. If it is too long, it will indirectly increase the heating effect, and the indoor heating will be too slow and cause no heat.
Reason 7. The pressure of natural gas or gas is not enough, which requires consultation with the gas company to increase the pressure of the gas source.
Wall-hung boiler hot water solution:
First, if it is not the machine itself, the user can look at the maintenance staff to learn to solve their own operations, such as a simple board cleaning cleaning, water flow sensor cleaning, etc., can appear later to solve.
Second, tap water supplement with a device to prevent scale condensation, to a certain extent, can prevent this phenomenon.
Third, when installing, increase the necessary filter in the incoming water pipeline, can filter out the impurities in the water; increase the flow regulator and gas regulator, water flow and gas flow can be more stable.
Summary: On the floor heating is not hot , I hope to help you, more decoration information, all in this site, so stay tuned.